Phase holograms for the three
Scientific Reports volume 13, Article number: 9160 (2023) Cite this article
176 Accesses
Metrics details
Acoustic radiation forces can remotely manipulate particles. Forces from a standing wave field align microscale particles along the nodal or anti-nodal locations of the field to form three-dimensional (3D) patterns. These patterns can be used to form 3D microstructures for tissue engineering applications. However, standing wave generation requires more than one transducer or a reflector, which is challenging to implement in vivo. Here, a method is developed and validated to manipulate microspheres using a travelling wave from a single transducer. Diffraction theory and an iterative angular spectrum approach are employed to design phase holograms to shape the acoustic field. The field replicates a standing wave and aligns polyethylene microspheres in water, which are analogous to cells in vivo, at pressure nodes. Using Gor’kov potential to calculate the radiation forces on the microspheres, axial forces are minimized, and transverse forces are maximized to create stable particle patterns. Pressure fields from the phase holograms and resulting particle aggregation patterns match predictions with a feature similarity index > 0.92, where 1 is a perfect match. The resulting radiation forces are comparable to those produced from a standing wave, which suggests opportunities for in vivo implementation of cell patterning toward tissue engineering applications.
Remote manipulation of microparticles is important for noncontact applications including micro- and nanofabrication, lab-on-chip technologies, and tissue engineering. Tissue engineering provides an alternative approach to replace injured or disease organs or tissue1,2. Spatial patterning of cells into microstructures to form two- and three-dimensional (2/3D) assemblies is essential for providing a shape or structure for complex tissue regeneration3,4,5. 3D structural cellular arrangements have higher success in engineered tissue applications6,7,8. Several methods have been used to pattern cells in vitro using polymer matrix templates9 and bioprinting10. These methods have their advantages and drawbacks. Bioprinting can achieve complex desired shapes, but the cellular structure is constructed in a point-by-point manner, a time consuming approach that requires a complex setup10. Meanwhile, matrix-based methods pattern molds by changing the matrix properties, which is a more rapid method but is not suitable for complex shapes11,12. An alternative method is acoustic manipulation which is capable of remotely arranging a large number of cells simultaneously without direct physical contact with the cells13,14. Cells exposed to an acoustic field scatter the field leading to an acoustic radiation force that can spatially reposition the cell15.
Acoustic radiation forces have been applied for a wide variety of remote manipulation applications, such as microbubbles16 or solid objects in vivo17, or selective single cell18 or small particle manipulation for in vitro research19. The use of radiation forces to move a mass of particles form 3D structures is of particular interest. Most rapid and non-invasive 3D alignment of microstructures have utilized a standing wave8,20,21,22 generated by a transducer and a reflector, or multiple transducers facing each other. This setup forms alternating planes of zero and high pressure amplitude, known as nodes and antinodes, that are perpendicular to the propagation direction and are spaced at half-wavelength intervals. Acoustic radiation forces imparted by a standing wave direct microparticles or cells towards the nodes or antinodes of the field depending on their acoustic properties relative to those of the surrounding medium23. For tissue engineering applications, the 3D microstructure can be held in position using photopolymers24,25 or a hydrogel medium26,27,28,29,30. This acoustic patterning technology holds promise as a tool for tissue engineering.
An important goal of tissue engineering is to assemble cellular structures in vivo directly. It was previously shown that a two-transducer system can generate a standing wave where their beams crossed to pattern endothelial cells forming a complex 3D microvessel network in a hydrogel volume in vitro3,27 and in vivo31 site-specifically and non-invasively. However, standing waves are difficult to generate in some regions of the body because of limits on where transducers can be placed on the body to transmit sound without obstruction. Conversely, a traveling wave cannot hold a stable pattern and pushes the particles away in the direction of propagation. In this work, we utilized phase holograms that can produce complex pressure fields from one transducer32 to create a 3D standing wave pattern similar to the one used to form a 3D microvessel network31,33,34. Previous work has utilized phase holograms to achieve complex 2D particle patterning with radiation forces35 and acoustic streaming36,37, while relying on boundaries to mitigate the radiation forces from a single transducer from pushing the particles away. However, these conditions cannot be generated in most in vivo scenarios.
Here, we used a holographic lens with one transducer to assemble suspended microspheres using acoustic radiation forces only along a predefined 3D pattern in vivo-mimicking environment while the spheres experience no pushing acoustic forces. Our goal was to use a single transducer to create an acoustic field of parallel planes of pressure nodes and antinodes (Fig. 1a,b) to suspend cell-mimicking particles in this pattern over several wavelengths in the axial distance. Such a field is similar to a standing wave, but the planes lay parallel to and with their normal orthogonal to the acoustic axis. For particles much smaller than the acoustic wavelength, the radiation forces are predicted by the Gor’kov potential23, where the forces are proportional to the gradients of acoustic pressure and velocity, and the relative properties of the particle and medium. Particles that are neutrally buoyant—cells in water are nearly so—eliminate the velocity gradient contributions to the radiation forces. Thus, the radiation forces and particle alignment are dependent on the pressure gradients alone. We designed phase holograms using an analytical method and the iterative angular spectrum approach (IASA)32 to fabricate lenses that produce parallel pressure planes with zero pressure gradient in the axial direction over a designated region at a specified distance from the transducer. Therefore, the radiation forces align neutrally buoyant cell-mimicking microspheres in water along the desired parallel plane distribution with no axial motion present in a cuvette to mimic conditions for in vivo implementation, see Fig. 1c–f.
Acoustic radiation forces align particles along parallel planes of pressure. Particles are dispersed in a container (a), and are aligned in a standing wave field using a transducer and a reflector (b). Our work uses a phase hologram (c) to fabricate a holographic lens coupled with a transducer to create pressure planes that are parallel to the wave propagational axis (d). The pressure planes have no axial pressure gradient near the region of interest zi where the Gor’kov potential is directly proportional pressure amplitude for particles with density similar to the surrounding medium (e) and the resulting forces aligns the polystyrene microspheres along the nodal pressure regions (f).
The results were produced separately for three different custom-made transducers, each with a holographic lens to synthesize a unique pressure field. Lenses 1 and 2 were attached to 1.5-MHz, 45-mm square piezoceramic elements while lens 3 was attached to a 2-MHz, 35-mm circular piezoceramic element (see Supplementary Information Fig. S3). Lens 1 was composed of two congruent rectangles angled toward each other by θ = 30˚ from the horizontal (Fig. 2a,b) with the acoustic rays entering the water at an angle of entry θw = 13° to form two plane waves intersecting at 2θw. This lens generated a forward propagating wave, with a standing wave component in the transverse dimension that produced parallel planes of pressure separated by do = λ/[2 × sin (θ − θw)] = 2.22 mm where λ is the acoustic wavelength (see "Methods").
Results of holographic acoustic fields. Each row represents the result from lens 1 (top), 2 (middle) and 3 (bottom). The columns are phase holograms (a,e,i) used to fabricate the lenses (b,f,j), simulation of desired image of pressure amplitude in the transverse xy-plane (c,g,k), and holography scan measurement of the acoustic fields at the desired image plane in the transverse xy-plane (d,h,l). In the acoustic pressure fields subplots, the solid white border outlines the piezoceramic active acoustic element. The field produced from lens 1 is equivalent to that of two sources with their acoustic axes separated by an angle 2θw (b) which outputs approximately a standing wave in the transverse direction (c,d). Lenses 2 and 3 produced five parallel axial planes as predicted by simulation (h,l). For lens 2, the outer planes are weakly formed and never achieve full illumination (h), while lens 3 produced five planes with outer planes slightly weaker than predicted by simulation (g,h).
The pressure field from lenses 2 and 3 (Fig. 2g,k) were generated by using the phase boundary condition obtained from IASA (Fig. 2e,i) to produce the desired pressure image at 46 and 35 mm from the source. IASA iterates over the phase boundary condition until convergence is reached to satisfy a target pressure image at the specified location32 (see "Methods"). A target location that is too close to, or too far from, the source and the phase hologram cannot synthesize and maintain uniform parallel pressure planes over a distance. Therefore, the imposed target pressure image location was placed in the translational region of the field, near the end of the Fresnel region and before the Fraunhofer diffraction region. This region allowed the target image to be at a distance where the development of spherical spreading can maintain the shaped image for 2–3λ axial distance. For sources with the effective radius much larger than the wavelength, the translational region starts prior to the last on-axis pressure amplitude maximum38(see "Methods"). The phase boundary condition39 was unwrapped to achieve a continuously smooth morphology of the fabricated lens surface (see Supplementary Information).
Acoustic holography40 was performed to scan the pressure fields produced by the transducers coupled with the holographic lenses submerged in water. The field was scanned in a plane orthogonal to the acoustic axis by a 200-μm diameter capsule hydrophone (HGL-0200, Onda Corp., CA, USA) that recorded the waveform in a square grid of points at a maximum of λ/2 grid spacing for all transducers40. The recorded waveforms were used to find the angular spectrum of the holographic lens and construct the source vibration and the 3D complex pressure and particle velocity field (see "Methods").
Figure 2 shows the source phase, holographic lens, and the pressure amplitude measured and simulated at the desired target distance from the source. The average spacing between parallel planes from lens 1 was measured to be do = 2.26 ± 0.027 mm with an error of 2.15 ± 1.22%. Using this value of do, θw was calculated to be 12.75° ± 0.17°. The feature similarity index (FSI)41 provides a value (0–1) on the agreement between measured and simulated patterns with 1 being perfect agreement. Pressure measurements for lens 1, 2, and 3 achieved an FSI of 0.950, 0.939, and 0.953 respectively. The pattern of parallel planes produced from lens 1 extended from 20 to 45 mm in the axial direction (Supplementary Information Fig. S4), while the desired pressure images from lens 2 and 3 were formed at 48.0 and 35.6 mm from the source. The difference between the imposed and measured pressure locations was attributed to the mismatch between the sound speed in water and lens material which was not accounted for in the simulation.
Measurement of the pressure field from lens 2 (Fig. 2f) showed the formation of three distinct planes, with the outer planes having lower intensity than the center. The three planes extended for 2.5 mm (2.5λ) with equal and uniform pressure level over the central 1.5 mm axial extent while the 0.5 mm pre and post central region had higher variance between the planes’ intensity levels (see Fig. S4). Similarly, lens 3 formed five parallel axial planes extending over 1.5 mm (2λ). The outer planes had a relatively lower intensity level than was predicted by simulation (Fig. 2l and see Supplementary Information).
Gor’kov potential was constructed from the measured pressure and velocity fields to predict the acoustic radiation forces on polyethylene microspheres (75–90 μm diameter) along different spatial positions (see Methods). The radiation force aligned the microspheres in the nodal planes, which are marked by white lines in Fig. 3. In the xy transverse plane, the force in the x-direction was zero at the nodes and antinodes (Fig. 3c,g,k). The potential's local minima coincided with the pressure nodes where the radiation forces were stable and spheres were directed toward the nodes (Fig. 3b,f,j). The microspheres aligned and formed a minimum of 6, 4 and 4 vertical lines in the xy-plane from the radiation force imparted by lens 1, 2 and 3, respectively. The pressure field produced from lens 3 contained regions of slightly lower pressure than the surrounding pressure within an antinode, thus creating secondary potential energy minima where trapping occurred as indicated by short white lines in Fig. 3i–l. The stable particle distribution was predicted from the local minima of Gor’kov's potential42 as shown in Fig. 3d,h,l. Lenses 2 and 3 exhibited potential energy saddle points42 along the y-dimension where a small perturbation could cause microspheres to become unstable and move in y. However, these points had two-dimensional xz stability and were surrounded by 3D stable regions, which stabilized the particles in those saddles (Fig. 3d,h,l).
Acoustic radiation forces imparted on polyethylene microspheres that are 75–90 μm in diameter under acoustic pressure values obtained in Fig. 2. The direction of the force in the xy-plane for all lenses (a,e,i) aligns the spheres in pressure nodes. Zero force locations in the xy-plane are where the potential energy is at minimum (b,f,j) as marked by the white lines indicating particle agglomeration positions. The alignment position of particles with three-dimensional stability are shown for all lenses (d,h,l) where saddle points with xz-stability (violet dots) are surrounded by fully stable positions (pink dots). Lens 3 had additional local minima where spheres aligned along shorter vertical planes between the main stability planes (i–l).
To validate predictions, we aligned microspheres in a custom-made cuvette made from an acoustically transparent membrane material (Fig. 4). Transducers were submerged in a degassed water tank with the cuvette. A few drops of microspheres solution (0.032 g/mL) were added inside the cuvette (see "Methods"). The cuvette dimension along the axial direction was approximately 1 cm. A 1.2-mm thick laser sheet illuminated the transverse plane of interest to photograph and record the microsphere suspension and patterning. The maximum pressure produced for the experiment was 0.5, 0.6 and 1.7 MPa for lenses 1, 2 and 3 respectively. No axial motion in the region of interest was observed. Figure 4 shows the alignment of microspheres between antinodes for all lenses. All lenses patterned microspheres along the nodes as predicted and shown in Fig. 3, with the outer lines having regions with low concentration of particles due to the weaker acoustic intensity, thus weaker forces. The horizontal spacings between the lines for lens 1–3 from the holography-scan-based force measurements in Fig. 3d,h,l are 2.34 ± 0.17, 1.75 ± 0.08, and 1.85 ± 0.15 mm, while from Fig. 4, the spacings were measured to be 2.37 ± 0.32, 1.57 ± 0.18, and 1.35 ± 0.14 mm, respectively. Supplementary Movies S1–S3 show alignment of particles from the acoustic exposure of each lens. The alignment of spheres in the secondary trapping regions produced from lens 3 was observed using a high concentration of microsphere solution to show the antinodes by a complete absence of microspheres (see Supplementary Figs. S7; Movie S4).
Setup of acoustic radiation force alignment of polyethylene microspheres in water (a). Plots (b–d) capture images of alignment where white arrows mark the location of nodal pressure planes. Lens 1 strongly aligns microspheres along six vertical lines between the anti-pressure nodes (b). Lens 2 forms two vertical lines of microspheres between three anti-nodal vertical pressure planes with slightly weaker alignment on the outside left and the weakest alignment plane is on the outside right marked by dashed white arrows (c). Similarly, lens 3 forms 5 anti-nodal pressure planes with 4 vertical trapping regions in between, with the weakest trapping located on the outside right and marked by a white dashed arrow (d). The scale bar at the bottom of each subplot (b–d) is 1 mm in length. A high concentration of polyethylene microspheres was used to visualize the acoustic radiation force alignment and secondary trapping regions from lens 3 by pushing the microspheres from the anti-nodal planes forming a negative image in Fig. S7, and Movie S4.
The net force due to the radiation and hydrodynamic forces was calculated to show the trajectory of a single microsphere placed in water on the x-axis at the target pressure plane location with a maximum pressure amplitude equal to 1 MPa (see "Methods"). The trajectory of microsphere from different initial positions along x in the acoustic field was plotted in Fig. 5. Microspheres placed near stable positions translated toward a nodal location, while those placed near unstable positions close to an antinode were pushed away and floated with a negligible inertia before eventually reaching a stable position. The net restoring force acting on a microsphere could reach up to tenfold its weight, with stronger focusing of higher frequency producing the largest radiation force, as shown by lens 3.
Normalized forces experienced by a single polyethylene microsphere located at the target pressure image location at different starting x positions for lenses 1 to 3 (a–c). The forces are normalized by the microsphere's weight in a vacuum. The solid curve is the acoustic radiation force, lines with arrows are net force when the initial position is at stable (solid circle) or unstable (open circle) region before the acoustic exposure. Locations with zero x-component radiation acoustic force are marked by square that show stable (solid) or unstable (open) equilibrium.
We used lenses to shape travelling waves and align microspheres along parallel pressure planes within a limited 3D space at specified locations. Lens 1 produced parallel planes over an extended distance of approximately 25λ in the nearfield, similar to a non-diffracting Bessel beam43 that can be experimentally created by an axicon44. Both lens 1 and Bessel beams share similar boundary conditions. A Bessel beam has an axisymmetric vibrational amplitude and a characteristic angle, while lens 1 has a uniform vibrational amplitude symmetric about the y-axis and an entry angle (see derivation in Supplementary Information). Holographic lenses 2 and 3 created parallel pressure planes that extended for only 2–3λ but allowed for precision in designing 3D pressure fields and complex patterns. However, the field shaping was confined to a nearfield region of the source before the spreading of the acoustic beam, which occurs proximal to the Rayleigh distance defined as the source area over the wavelength45. The distance of manipulation is constrained by the source size and frequency, while the highest pressure pattern resolution is limited to λ/2. Sensitivity analysis of the source boundary conditions (see Supplementary Information) showed greater dependence on the phase than the amplitude boundary condition for higher pressure field accuracy. Phase unwrapping produced the most accurate phase boundary condition but resulted in higher attenuation, causing weaker alignment forces of the outer planes. Therefore, the surface morphology chosen for the lens was critical for accuracy.
The particle patterning matched our theoretical prediction and achieved suspension of particles without motion in the axial direction as intended. We calculated radiation forces from maximum acoustic pressure of 1 MPa on mouse embryonic myofibroblasts cells34 (with density ρ = 1.05 g/cm3, sound speed c = 1529 m/s, and r = 3 μm) from lenses 1–3 to be 2.33 ± 0.350, 4.51 ± 3.16, and 4.62 ± 1.21 piconewtons (pN). These values are comparable to those shown in Ref.34 that reached 2.2 pN from a standing wave pattern at an amplitude of 0.2 MPa. These results demonstrate the feasibility of in vivo cell patterning using single transducer methods.
We designed and fabricated holographic lenses to reshape the pressure field and produce pressure planes that were parallel to the acoustic axis and mimicked standing wave behavior over a limited region remote from the transducer surface. The pressure field generated acoustic radiation forces that manipulated subwavelength particles and steered them to the nodes while avoiding undesirable axial motion. Calculations showed that the forces produced by the propagating wave were equivalent to those produced by a standing wave, with the forces up to tenfold greater than the particle weight. This technology has the potential for controlled cellular patterning for in vivo vascularization and other tissue engineering applications.
Lens 1 was designed using two angled congruent sides facing each other with an angle equal to 2θ to produce a pressure in three dimensions defined by:
where k = 2π/λ, kx, ky, and kz are the x, y and z wavenumbers, respectively. And
where \({k}_{1}= {k}_{x}\mathrm{cos}{\theta }_{w}+\sqrt{{k}^{2}-{k}_{x}^{2}-{k}_{y}^{2}}\mathrm{sin}{\theta }_{w}\), \({k}_{2}= {k}_{x}\mathrm{cos}{\theta }_{w}-\sqrt{{k}^{2}-{k}_{x}^{2}-{k}_{y}^{2}}\mathrm{sin}{\theta }_{w}\), Lx and Ly are the x and y dimensions of the full rectangular source, υo is the velocity boundary condition, and θw is the angle of entry of acoustic rays into the water medium defined from Snell's law, see Supplementary Information for full derivation of Eq. (2).
IASA32 was used to design lens 2 and 3 by iterating over the source phase boundary condition to reach a target pressure image imposed at a specific axial distance from the source. To determine the location of the target, the Rayleigh integral45 was used to simulate the pressure amplitude distribution on the acoustic axis. The last pressure amplitude maximum was then chosen as the desired distance. The imposed pressure target for each lens was a binary image of five vertical lines, each 10 mm in height and equidistant from each other. The imposed pressure targets for each lens are shown in Supplementary Information Fig. S2. The termination of the iteration was defined to be when the difference between the second norm of the phase boundary condition from two consecutive iteration steps to be \({\Vert {\phi }_{i}-{\phi }_{i-1}\Vert }_{2}\)≤ 1e−3.
A continuous wave (CW) analysis40 of the hydrophone scan at the plane z = zp was used to record the acoustic hologram of the source and to construct the complex pressure in 3D (see Supplementary Information). The angular spectrum at the scan plane zp was defined as such:
which was used to construct the complex pressure amplitude at a plane normal to the acoustic axis located at zi:
For a harmonic wave, the particle velocity complex amplitude is expressed from the complex amplitude of the acoustic pressure to be:
Therefore, the jth component of the velocity vector from Eq. (3) is:
Acoustic radiation forces on the microspheres are calculated from Gor’kov potential since the spheres are much smaller than the acoustic wavelength (r/λ ≈ 0.1). For a harmonic burst, the radiation force on a particle is defined as:
where the Einstein summation notation is used (see Supplementary Information for derivation). The force is defined as \(\overrightarrow{F}=-\nabla U\) where Gor’kov potential U23 is:
And \(f_{1} = 1 - \frac{{{\text{c}}^{2} \rho }}{{c_{l}^{2} \rho _{*} }}\frac{1}{{1 - 4c_{t}^{2} /3c_{l}^{2} \$ }}\) and \({f}_{2}=\frac{2\left({\rho }_{*}-\rho \right)}{(2{\rho }_{*}+ \rho )}\)46.
The radius of the microsphere is r, and the longitudinal and transverse sound speeds, and density are cl (2566 m/s), ct (1273 m/s) and ρ* (0.922 g/cm3)47, while ρ (1 g/cm3) and c (1500 m/s) are those of the surrounding water, P and \(\overrightarrow{v}\) are the incident acoustic pressure and particle velocity complex amplitudes.
Approximately 0.3 g of polyethylene microspheres were placed in a glass bottle with few drops of liquid detergent added as a surfactant, then 125 mL of deionized and degassed water was added to the bottle. A magnetic bar was inserted into the bottle, and it was continuously stirred by a magnetic mixer throughout the experiments. Microspheres were placed few drops at a time in a cuvette 3D printed from polylactic acid (PLA) filament (Ultimaker, Framingham, MA) with acoustically transparent side walls made from 12.7-μm, polyester, clear film (McMaster-CARR, Elmhurst, IL). All transducers were operated in a pulsed mode, transmitting 100-cycle pulses at 10% duty cycle. Microspheres aligned along the nodal planes created scattering of the light and were visible. A camera was placed outside the tank facing the transducer to capture the alignment. The alignment images presented in Fig. 4 used a brightness threshold as cutoff to improve the contrast of regions where microspheres agglomerated.
A polyethylene microsphere placed in the acoustic field will experience radiation forces imparted by the acoustic field and hydrodynamic drag by fluid due to the microsphere's motion relative to the surrounding fluid. The sphere will undergo Stokes’ drag, virtual mass, and Basset–Boussinesq history forces48. Generally the inertial forces are minimal and only Stokes’ drag is important49. However, we calculated the added mass since the microspheres have a density similar to the surrounding water, and accounted for Basset–Boussinesq history force to account for the unsteady flow due to the initial sudden acceleration of the sphere, which has been shown to affect the early time of motion50. It is assumed that fluid streaming from acoustic exposure is minimal due to the presence of the cuvette walls51. Thus, only the sphere's motion contributes to the drag forces. The total drag forces on the sphere are defined as follow:
where the terms from left to right are defined as Stokes’ drag, added mass, and Basset forces52. The position of the sphere is x, \({K}_{\mu }\left(t\right)=1/\sqrt{\mu \pi t/\rho {r}^{2}}\) is the memory kernel of the Basset term for a rigid sphere with its relative viscosity to water is infinite48,52, μ = 1.016 × 1e−3 Pa·s is the dynamic viscosity of water. The net force Fnet experienced by the microsphere is given by:
where m is the mass of the polyethylene microsphere.
The order of Eq. (7) is reduced and rewritten as a system of first order differential equations to solve for a single microsphere's trajectory using Runge–Kutta iterative method53 with MATLAB® built-in solver.
It is important to mention that Fnet in Eq. (7) is for a single microsphere and the radiation force term Fa does not take into consideration the scattering from neighboring particles30. The radiation force calculation in Eq. (5) assumes an inviscid fluid because the viscous fluid layer or acoustic boundary layer surrounding the particle is much less than the particle radius54. The maximum acoustic boundary layer is \(\delta =\sqrt{2\mu /\rho \omega }=0.5, \mathrm{ \mu m}\), while the microsphere diameter range is 75–90 μm. Furthermore, fluid viscosity is the only opposing force to the radiation force, thus the assembly speed is dependent on the fluid viscosity. In an inviscid fluid, a microsphere placed slightly off from an acoustically stable equilibrium position will oscillate about the position as in an undamped mass-spring system.
The data that support the findings of this study are available in the Supplementary information files.
Olson, J. L., Atala, A. & Yoo, J. J. Tissue engineering: Current strategies and future directions. CMJ 47, 1–13 (2011).
CAS PubMed PubMed Central Google Scholar
Jaklenec, A., Stamp, A., Deweerd, E., Sherwin, A. & Langer, R. Progress in the tissue engineering and stem cell industry "Are we there yet?". Tissue Eng. Part B Rev. 18, 155–166 (2012).
Article PubMed Google Scholar
Comeau, E. S., Hocking, D. C. & Dalecki, D. Ultrasound patterning technologies for studying vascular morphogenesis in 3D. J. Cell Sci. https://doi.org/10.1242/jcs.188151 (2016).
Article PubMed Google Scholar
Hitchcock, T. & Niklason, L. Lymphatic tissue engineering: Progress and prospects. Ann. N. Y. Acad. Sci. 1131, 44–49 (2008).
Article ADS PubMed PubMed Central Google Scholar
Dalecki, D. & Hocking, D. C. Ultrasound technologies for biomaterials fabrication and imaging. Ann. Biomed. Eng. 43, 747–761 (2015).
Article PubMed Google Scholar
Gjorevski, N. et al. Designer matrices for intestinal stem cell and organoid culture. Nature 539, 560–564 (2016).
Article CAS PubMed Google Scholar
Young, J. L., Holle, A. W. & Spatz, J. P. Nanoscale and mechanical properties of the physiological cell-ECM microenvironment. Exp. Cell Res. 343, 3–6 (2016).
Article CAS PubMed Google Scholar
Koo, K. I., Lenshof, A., Huong, L. T. & Laurell, T. Acoustic cell patterning in hydrogel for three-dimensional cell network formation. Micromachines 12, 1–12 (2021).
Google Scholar
Jeon, H. et al. Directing cell migration and organization via nanocrater-patterned cell-repellent interfaces. Nat. Mater. 14, 918–923 (2015).
Article ADS CAS PubMed PubMed Central Google Scholar
Shanjani, Y., Siebert, S. M., Ker, D. F. E., Mercado-Pagán, A. E. & Yang, Y. P. Acoustic patterning of growth factor for three-dimensional tissue engineering. Tissue Eng. Part A 26, 602–612 (2020).
Article CAS PubMed PubMed Central Google Scholar
Falconnet, D., Csucs, G., Michelle Grandin, H. & Textor, M. Surface engineering approaches to micropattern surfaces for cell-based assays. Biomaterials 27, 3044–3063 (2006).
Article CAS PubMed Google Scholar
Rajagopalan, P., Marganski, W. A., Brown, X. Q. & Wong, J. Y. Direct comparison of the spread area, contractility, and migration of balb/c 3T3 fibroblasts adhered to fibronectin- and RGD-modified substrata. Biophys. J. 87, 2818–2827 (2004).
Article ADS CAS PubMed PubMed Central Google Scholar
Coakley, W. T., Bardsley, D. W., Grundy, M. A., Zamani, F. & Clarke, D. J. Cell manipulation in ultrasonic standing wave fields. J. Chem. Technol. Biotechnol. 44, 43–62 (1989).
Article Google Scholar
Coakley, W. T., Whitworth, G., Grundy, M. A., Gould, R. K. & Allman, R. Ultrasonic manipulation of particles and cells. Ultrasonic separation of cells. Bioseparation 4, 73–83 (1994).
CAS PubMed Google Scholar
Settnes, M. & Bruus, H. Forces acting on a small particle in an acoustical field in a viscous fluid. Phys. Rev. E Stat. Nonlinear Soft Matter Phys. 85, 1–12 (2012).
Article Google Scholar
Baresch, D. & Garbin, V. Acoustic trapping of microbubbles in complex environments and controlled payload release. Proc. Natl. Acad. Sci. USA 117, 15490–15496 (2020).
Article ADS CAS PubMed PubMed Central Google Scholar
Ghanem, M. A. et al. Noninvasive manipulation of objects in a living body. Rev.
Baudoin, M. et al. Spatially selective manipulation of cells with single-beam acoustical tweezers. Nat. Commun. 11, 1–10 (2020).
Article MathSciNet Google Scholar
Marzo, A. & Drinkwater, B. W. Holographic acoustic tweezers. Proc. Natl. Acad. Sci. 116, 84–89 (2018).
Article ADS PubMed PubMed Central Google Scholar
Caleap, M. & Drinkwater, B. W. Acoustically trapped colloidal crystals that are reconfigurable in real time. Proc. Natl. Acad. Sci. USA 111, 6226–6230 (2014).
Article ADS CAS PubMed PubMed Central Google Scholar
Garvin, K. A., Dalecki, D., Yousefhussien, M., Helguera, M. & Hocking, D. C. Spatial patterning of endothelial cells and vascular network formation using ultrasound standing wave fields. J. Acoust. Soc. Am. 134, 1483–1490 (2013).
Article ADS CAS PubMed PubMed Central Google Scholar
Dalecki, D. et al. Guiding tissue regeneration with ultrasound in vitro and in vivo. In (eds. George, T., Dutta, A. K. & Islam, M. S.) 94670F (2015). https://doi.org/10.1117/12.2177046.
Gor’kov, L. P. On the forces acting on a small particle in an acoustical field in an ideal fluid. Sov. Phys. Dokl. 6, 773–775 (1962).
ADS Google Scholar
Greenhall, J. & Raeymaekers, B. 3D printing macroscale engineered materials using ultrasound directed self-assembly and stereolithography. Adv. Mater. Technol. 2, 1–7 (2017).
Article Google Scholar
Llewellyn-Jones, T. M., Drinkwater, B. W. & Trask, R. S. 3D printed components with ultrasonically arranged microscale structure. Smart Mater. Struct. 25, 1–6 (2016).
Article Google Scholar
Armstrong, J. P. K. et al. Engineering anisotropic muscle tissue using acoustic cell patterning. Adv. Mater. 30, 1–7 (2018).
Article Google Scholar
Cheng, K. W. et al. Fast three-dimensional micropatterning of PC12 cells in rapidly crosslinked hydrogel scaffolds using ultrasonic standing waves. Biofabrication 12, 25 (2020).
Google Scholar
Yunus, D. E., Sohrabi, S., He, R., Shi, W. & Liu, Y. Acoustic patterning for 3D embedded electrically conductive wire in stereolithography. J. Micromech. Microeng. 27, 045016 (2017).
Article PubMed PubMed Central Google Scholar
Melchert, D. S. et al. Flexible conductive composites with programmed electrical anisotropy using acoustophoresis. Adv. Mater. Technol. 4, 1900586 (2019).
Article Google Scholar
Melchert, D. S. et al. Anisotropic thermally conductive composites enabled by acoustophoresis and stereolithography. Adv. Funct. Mater. 32, 2201687 (2022).
Article CAS Google Scholar
Dalecki, D., Comeau, E. S., Vander Horst, M. A., Raeman, C. H. & Hocking, D. C. Acoustic patterning of endothelial cells in vivo to produce microvascular networks. J. Acoust. Soc. Am. 150, A57–A57 (2021).
Article ADS Google Scholar
Melde, K., Mark, A. G., Qiu, T. & Fischer, P. Holograms for acoustics. Nature 537, 518–522 (2016).
Article ADS CAS PubMed Google Scholar
Garvin, K. A., Dalecki, D. & Hocking, D. C. Vascularization of three-dimensional collagen hydrogels using ultrasound standing wave fields. Ultrasound Med. Biol. 37, 1853–1864 (2011).
Article PubMed PubMed Central Google Scholar
Garvin, K. A., Hocking, D. C. & Dalecki, D. Controlling the spatial organization of cells and extracellular matrix proteins in engineered tissues using ultrasound standing wave fields. Ultrasound Med. Biol. 36, 1919–1932 (2010).
Article PubMed PubMed Central Google Scholar
Melde, K. et al. Acoustic fabrication via the assembly and fusion of particles. Adv. Mater. 30, 1–5 (2018).
Article ADS Google Scholar
Ma, Z. et al. Acoustic holographic cell patterning in a biocompatible hydrogel. Adv. Mater. 32, 1–6 (2020).
ADS Google Scholar
Gu, Y. et al. Acoustofluidic holography for micro-to nanoscale particle manipulation. ACS Nano 14, 14635–14645 (2020).
Article CAS PubMed PubMed Central Google Scholar
Zemanek, J. Beam behavior within the nearfield of a vibrating piston. J. Acoust. Soc. Am. 49, 181–191 (1971).
Article ADS Google Scholar
Zhao, Z. et al. Robust 2D phase unwrapping algorithm based on the transport of intensity equation. Meas. Sci. Technol. 30, 015201 (2019).
Article ADS Google Scholar
Sapozhnikov, O. A., Tsysar, S. A., Khokhlova, V. A. & Kreider, W. Acoustic holography as a metrological tool for characterizing medical ultrasound sources and fields. J. Acoust. Soc. Am. 138, 1515–1532 (2015).
Article ADS PubMed PubMed Central Google Scholar
Lin, Z., Lei, Z., Xuanqin, M. & Zhang, D. FSIM: A feature similarity index for image quality assessment. IEEE Trans. Image Process. 20, 2378–2386 (2011).
Article ADS MathSciNet MATH Google Scholar
Barmatz, M. & Collas, P. Acoustic radiation potential on a sphere in plane, cylindrical, and spherical standing wave fields. J. Acoust. Soc. Am. 77, 928–945 (1985).
Article ADS MATH Google Scholar
Lu, J. Y. Designing limited diffraction beams. IEEE Trans. Ultrason. Ferroelectr. Freq. Control 44, 181–193 (1997).
Article CAS PubMed Google Scholar
Arlt, J. & Dholakia, K. Generation of high-order Bessel beams by use of an axicon. Opt. Commun. 177, 297–301 (2000).
Article ADS CAS Google Scholar
Blackstock, D. T. Fundamentals of Physical Acoustics (Wiley, 2000).
Google Scholar
Sapozhnikov, O. A. & Bailey, M. R. Radiation force of an arbitrary acoustic beam on an elastic sphere in a fluid. J. Acoust. Soc. Am. 133, 661–676 (2013).
Article ADS PubMed PubMed Central Google Scholar
Szabo, T. L. & Wu, J. A model for longitudinal and shear wave propagation in viscoelastic media. J. Acoust. Soc. Am. 107, 2437–2446 (2000).
Article ADS CAS PubMed Google Scholar
Galindo, V. & Gerbeth, G. A note on the force on an accelerating spherical drop at low-Reynolds number. Phys. Fluids A 5, 3290–3292 (1992).
Article ADS MATH Google Scholar
Bruus, H. Acoustofluidics 7: The acoustic radiation force on small particles. Lab Chip 12, 1014–1021 (2012).
Article CAS PubMed Google Scholar
Changf, E. J. & Maxey, M. R. Unsteady flow about a sphere at low to moderate Reynolds number. Part 2. Accelerated motion. J. Fluid Mech. 303, 133–153 (1995).
Article ADS MATH Google Scholar
Ghanem, M. A., Maxwell, A. D., Sapozhnikov, O. A., Khokhlova, V. A. & Bailey, M. R. Quantification of acoustic radiation forces on solid objects in fluid. Phys. Rev. Appl. 12, 44076 (2019).
Article ADS CAS Google Scholar
Legendre, D., Rachih, A., Souilliez, C., Charton, S. & Climent, E. Basset-Boussinesq history force of a fluid sphere. Phys. Rev. Fluids 4, 1–11 (2019).
Article Google Scholar
Dormand, J. R. & Prince, P. J. A family of embedded Runge–Kutta formulae. J. Comput. Appl. Math. 6, 19–26 (1980).
Article MathSciNet MATH Google Scholar
Doinikov, A. A. Radiation force due to a spherical sound field on a rigid sphere in a viscous fluid. J. Acoust. Soc. Am. 96, 3100–3105 (1994).
Article ADS Google Scholar
Download references
The work has been supported and funded by NIH K25-DK132416, NIH P01-DK043881, and University of Washington-Applied Physics Laboratory SEED Grant.
Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th St., Seattle, WA, 98105, USA
Mohamed A. Ghanem, Oleg A. Sapozhnikov & Michael R. Bailey
Department of Urology, School of Medicine, University of Washington, Seattle, WA, 98195, USA
Adam D. Maxwell & Michael R. Bailey
Department of Biomedical Engineering, University of Rochester, Rochester, NY, 14627, USA
Diane Dalecki
Physics Faculty, Moscow State University, Moscow, 119991, Russia
Oleg A. Sapozhnikov
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
You can also search for this author in PubMed Google Scholar
M.A.G., A.D.M., D.D., and M.R.B. conceived the concept. M.A.G. designed and executed the experiment, analyzed the data, and performed numerical simulation. A.D.M, and O.A.S. assisted with experimental setup. M.A.G. and O.A.S. derived and reviewed the theoretical concepts presented. All authors edited and revised the manuscript.
Correspondence to Mohamed A. Ghanem.
The authors declare no competing interests.
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Video 1.
Supplementary Video 2.
Supplementary Video 3.
Supplementary Video 4.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and Permissions
Ghanem, M.A., Maxwell, A.D., Dalecki, D. et al. Phase holograms for the three-dimensional patterning of unconstrained microparticles. Sci Rep 13, 9160 (2023). https://doi.org/10.1038/s41598-023-35337-8
Download citation
Received: 14 February 2023
Accepted: 16 May 2023
Published: 06 June 2023
DOI: https://doi.org/10.1038/s41598-023-35337-8
Anyone you share the following link with will be able to read this content:
Sorry, a shareable link is not currently available for this article.
Provided by the Springer Nature SharedIt content-sharing initiative
By submitting a comment you agree to abide by our Terms and Community Guidelines. If you find something abusive or that does not comply with our terms or guidelines please flag it as inappropriate.